Testing the Carl Zeiss Jena Einheitsdoppelfernrohr EDF 7x40

The rotational tests at the periodical reconditioning are very interesting.
Test conditions extracted from "A 050/1/501 Einheitsdoppelfernrohr 7x40 reconditioning" from 1982

  • Leak tightness
    Over pressure test: Pressure inside 50,7 kPa (this means low head 5 m)
    Specification: Pressure drop not allowed
  • Low head test
    Low head: 1 m
    Water temperature: 10 - 15 °C lower than unit temperature (this means underpressure inside the unit)
    Check-out time: 1 h
    Specification: No water nor fog inside
  • Drop test
    Drop height: 0,75 m
    Direction: 1 drop straight horizontal on broadside
  • Hit test
    Acceleration: 15 g
    Pulse duration: 5 - 10 ms
    Direction: 250 hits vertical on objective, 150 hits straight horizontal on broadside, 150 hits straight horizontal on narrow side
  • Hit test
    Acceleration: 120 g
    Pulse duration: 1 - 5 ms
    Direction: 2 hits vertical on objective, 4 hits straight horizontal on broadside, 4 hits straight horizontal on narrow side
  • Vibration stress
    Frequency range: 30 - 80 Hz
    Acceleration: 6 g
    Check-out time: 2 h vertical on objective side, 1 h straight horizontal on broadside, 1 h straight horizontal on narrow side
  • Cold resistance
    -50 °C, Check-out time 2 h, after unit equalization of requested temperature, rubber parts to -40 °C
  • Heat resistance
    +60 °C, Check-out time 2 h, after unit equalization of requested temperature
    Specification: No loss of grease
  • Cyclic temperature test
    Upper temperature: +60 °C
    Lower temperature: -50 °C
    Check-out time: 5 cycle every 2 h
    Specification: No loss of grease
  • Storage temperature
    +80 °C, Check-out time 1 h,  after unit equalization of requested temperature
    Specification: No loss of grease
  • Sea water resistance
    Temperature: +27 °C
    Check-out time: 168 h
    Compounding: sodium chloride 27 g/l, magnesium chloride 6 g/l, calcium chlorid (free of water) 1 g/l, potassium chlorid 1 g/l
    Specification: No corrosion

There are some near mint conditioned EDF 7x40 oB available here.

Newsletter

If you like, subsrcibe to our newsletter to keep informed about the latest news (new goods, etc.), if any.
  • Slideshow Frontpage 2 Bild 2
  • Slideshow Frontpage 2 Bild 1
  • Slideshow Frontpage 2 Bild 5
  • Slideshow Frontpage 2 Bild 4

Current

Some ex factory and new in box Hensoldt/Zeiss 8x30 M Fero-D 16 - still originally packed and not opened yet. Color is "Bronzegrün" (RAL 6031).
View more ...

 

Current

Some unissued, mint conditioned Carl Zeiss Jena "Einheitsdoppelfernrohr" EDF 7x40 out of former GDR Authorities NVA and MDI.
View more ...

 

You are here: Home Interesting Facts Testing the Carl Zeiss Jena Einheitsdoppelfernrohr EDF 7x40